<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-15 14-58-00
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.90 MHz 4/5, 52 dBuV RTL2
Pilot RDS Phase Difference
6.8 kHz 3.9 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 77 kHz 10060 66,1829
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
8,2 dBr 8,59 dBr 8,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL2 " F215 0 (No PTY) 1 0 1 2 14:57, 15.03.2025
RT
"RTL2, Le Son POP-ROCK "
AF EON
88.2, 89.1, 89.2, 90.1, 92.2, 92.4, 94.4, 95.9, 96.6, 97.3, 97.4, 98.0, 98.2, 98.3, 98.9, 99.3, 101.3, 103.2, 105.1, 105.3, 105.9, 106.0, 106.1, 106.9 MHz -
FM Scope Station: 105.90 MHz, signal: 4/5 (54 dBuV) Max at: 77 kHz MIN: 20 kHz % above 75 kHz: 66,1829 Acquired: 2025/03/15 14:56:56 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 8,9 dBr MIN: 8,2 dBr AVE: 8,59 dBr % above 10,0 dBr: 0,0 Last value: 8,8 dBr (2025/03/15 14:56:56) Station: 105.90 MHz, signal: 4/5 (53 dBuV) 14:50 14:51 14:52 14:53 14:54 14:55 14:56 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality